F and TW Standoff Check

Watch the 25 mm paddle or the trailing wire move as flow builds, and check whether a pipe standoff leaves room for it.

SwitchOFF

Force on the paddle 0.0 gf
switches at 17 gf, rated to 350 gf

The paddle is rigid: if it touches a wall, it stops.

SECTION · ALONG THE FLOWVIEW · ACROSS THE FLOWF Series head1" threadcable glandrestOFFONpipe wallview from aboveH 60still waterflowblade 28.5Ø102looking downstream · paddle face shown vertical
VIEW · FROM ABOVEflow

Cut at the tightest point. The wall is round and the blade is flat, so its two edges reach the wall first while its middle stays clear. That is why the paddle can look clear of the wall in the section when it has stopped. The dashed circle is the running clearance this check keeps.

Switch drawn to scale from the Kelco F-H-25B and TW-H-25B-XXX 3D models; pipe, standoff and socket shown in section. The section is seen from the Kelco logo side, with flow left to right. The view looks downstream.
ItemValueNote
Does it switch? switches ON and back OFF
Flow to switch ON60.8 L/minwater at 20 °C, straight pipe, by the Paddle Calculator's sums
Length below the thread140 mmpaddle as trimmed (166 mm untrimmed)
Length in the pipe, straight down80.0 mm78 % of pipe ID
Clear of the far wall, straight down22.0 mm OK
Bore needed in the standoff41.5 mm Ø45 clears
Blade goes through the bore when fittingat least 29.5 mm OK
Part of the sensor in still water60 mm raises the switching flow

What the sensor does. With no flow the sensor rests leaning upstream. Flow pushes it to just past vertical, where the switch closes, and more flow keeps pushing it until it hits the pipe, which stops it. The switch opens again only when the sensor falls most of the way back, so it doesn't chatter when the flow is close to the switching point.

The TW wire is flexible. Flow swings the wire until it hits the pipe at the edge of the opening. It then bends at the point of contact, and the flow pushes the rest of it on downstream. If it meets the far wall, it bends along it instead of jamming. A wire that touches before it switches still switches, but it rubs and wears, and its drag changes, so the switching flow shifts. Choose a shorter wire if you can.

What a standoff changes. The part of the sensor inside the standoff sits in still water, so less of it is pushed by the flow and the flow needed to switch goes up. The paddle also swings sideways inside the bore, so the bore must stay clear of it. The 28.5 mm blade must pass through the bore when fitting: an ordinary 1" pipe nipple (about 27 mm bore) is too small for it.

Where the paddle stops. The round wall sets its stop, as the view from above shows. A stop past the switching point is normal; a stop before it is a fault.

If the bore touches the paddle. A paddle resting on the standoff wall instead of its own stop starts nearer vertical. It switches at a lower flow and may drag or stick. Treat any red row as a fault, not a margin.

Limits of this check. It covers the 25 mm (1") F Series and the TW Series, and assumes top entry into a horizontal pipe. The bore figures in the table cover rest to the switching point; past that, the sensor goes on until it touches, as drawn. Flows and forces use the same sums as the Paddle Calculator, for water at 20 °C in a straight pipe, with only the part of the sensor in the pipe pushed and the standoff's longer lever. How far the sensor leans on the way to switching, and the wire's bend, are illustrative. A trimmed paddle is drawn cut square. Suitability for your installation is your decision: please check it against the product data sheet.