Seri P20Sakelar Aliran Inline Tahan Korosi

Sakelar aliran inline yang sederhana dan andal untuk cairan atau gas dalam tabung dan pipa berdiameter kecil. Mendeteksi aliran kontinu maupun berdenyut, tanpa bagian logam yang bersentuhan dengan cairan: ideal untuk air laut, air tanah, asam, dan larutan kimia.

Seri P20

Fitur

  • Mendeteksi aliran yang sangat rendah (P20-B dan P20-R mati pada 0.065 L/min)
  • Tanpa bagian logam yang bersentuhan dengan cairan
  • Dapat dipasang pada semua posisi
  • Mudah dipasang
  • Kemampuan aliran lewat yang tinggi
  • Tekanan nominal 18 bar
  • Kehilangan head yang sangat rendah
  • Deteksi aliran cairan atau gas
  • Aliran penyalaan 0.14 L/min (P20-B dan P20-R)
  • Rentang pH cairan 1 hingga 14
  • 3 modul listrik: output sakelar reed atau relai solid state

Bodi P20 memuat piston beralur. Aliran apa pun mendorong piston mundur dalam bodi hingga cairan melewati dan keluar dari sakelar. Piston berisi magnet yang menggerakkan sakelar reed eksternal melalui dinding polipropilena. Saat aliran berhenti, magnet kedua yang terpasang di bodi mengembalikan piston ke posisi mati: mekanisme berpegas magnetik yang sangat andal dan tahan korosi. Dapat dipasang pada semua posisi (termasuk terbalik). Tiga modul listrik memberikan banyak pilihan pengendalian. P20 standar dibuat seluruhnya dari polipropilena berpenguat kaca dengan seal O-ring nitrile, dan dipasok lengkap dengan spigot pipa dan union untuk pemasangan langsung pada perpipaan PVC atau ABS.

Informasi Lainnya

Pilih Model

Pemesanan: Model yang Tersedia

Nomor ModelDeskripsi
P20-B-20Dry reed switch S.P.S.T. N.O. — 50 W/VA, 250 V AC / 200 V DC, 1.5 A max. Not suitable for inductive loads. PLC and general control circuits. 20 NB process connection (suits PVC pipe).
P20-C-20Dry reed switch S.P.D.T. break before make — 20 W/VA, 140 V AC / 150 V DC, 1 A max. Not suitable for inductive loads. PLC and general control circuits. Less sensitive than B/R — < 0.50 L/min activation. 20 NB process connection (suits PVC pipe).
P20-R-20Solid-state relay (triac) S.P.S.T. N.O. — 740 W, 12 to 240 V AC, 4 A continuous (spike to 15 A); inductive loads 4 A at 240 V AC. AC control circuits and AC motor control. 20 NB process connection (suits PVC pipe).

Batas Operasi

Switching point on rising flow (P20-B / P20-R)0.14 L/min (water at ambient)
Switching point on falling flow (P20-B / P20-R)0.065 L/min (water at ambient)
Switching point on rising flow (P20-C)< 0.50 L/min (water at ambient)
Switching point on falling flow (P20-C)0.30 L/min (water at ambient)
Electrical response time (cessation of flow)0.4 seconds
Maximum operating pressure (static or dynamic, ambient)1800 kPa / 261 psi
Minimum burst pressure (ambient)9700 kPa / 1406 psi
Maximum liquid temperature80 °C at 1 bar absolute (de-rate pressure linearly)
Minimum liquid temperature-30 °C
Maximum recommended continuous flow rate (water)25 L/min
Liquid pH range1 to 14
Ingress protection ratingIP67

Dimensi

Dimensi Seri P20
Inline mount — 152 mm overall length, 134 mm face-to-face pipe gap, 50 × 85 mm housing. 3/4" BSP unions both ends with 15 NB pipe tails in PVC (21.3 mm diameter). M20 cable gland; IP67 enclosure.

Warning: Electrical Safety

The P20 Series flow switch is a mains voltage device. Death or serious injury may result if this switch is not correctly installed and operated. All electrical work on this switch must be performed by a fully qualified and licensed electrician.

Pressure De-rating at Elevated Temperatures

The 1800 kPa max operating pressure applies at ambient. Maximum operating pressure must be de-rated linearly with temperature, to a maximum of 1 bar absolute at 80 °C. Use this switch at elevated temperatures only in non-pressurised systems open to atmosphere.

All-Position Mounting

The P20 can be mounted in any orientation in pipework, including upside-down, with no adverse effects — the magnetically-sprung piston (rather than gravity) returns it to the off position when flow stops. There is a direction of flow arrow on the switch body; the switch will not operate against a reversed flow. Pipework can be used to support the switch, or the switch can be connected directly into valve manifolds or pump ports.

Liquid or Gas Flow

The P20 can detect the flow of liquids or gases, including vapour flow. Maximum temperature is 80 °C, and at 80 °C the operating pressure must not exceed 1 bar absolute.

Clean Fluid & Line Filtration

The P20 contains a close fitting piston and should only be used where the process fluid is reasonably clean and free of entrained or suspended material. Fluids containing large particulate matter, ferrous materials or fibrous matter should not be used in this switch. If the degree of contamination of the process fluid can’t be guaranteed, fit suitable line filtration upstream of the P20.

Pressure Limits & Water Hammer

Do not use the P20 where the line pressure exceeds 18 bar. In the interest of safety the switch has a burst pressure rating of >97 bar. Take care not to expose the switch to excess pressures such as may be generated by water hammer.

Materials & Housing

The standard P20 is made entirely from glass reinforced polypropylene with nitrile O-ring seals. The piston return and the electrical switching action use high power magnets operating through the solid body of the switch. The electrical housing is hose-proof and weatherproof to IP67 — dust tight, protected against temporary immersion and suitable for all outdoor exposed applications — with a built-in 20 mm cable gland for conduit or flexible cable entry (flexible cable up to 10 mm diameter, or a 20 mm conduit bush with the gland nut removed). Protect the switch from freezing.

Lid & Cable Gland

After installing or servicing, always replace the lid and fully tighten its lid screw and the cable gland. Never leave the lid off for extended periods: without its lid the switch is not water resistant or weather and insect proof and presents a potential shock hazard.

Typical Applications

Constant pressure pump control, loss of prime pump protection, water treatment control, irrigation control, chemical dosing systems, gland cooling systems and industrial process control.

Hazardous Areas

The P20-B and P20-C are simple apparatus under AS/NZS 60079.11 and may be used in a hazardous area only as part of an intrinsically safe circuit, connected through suitably certified associated apparatus. They are not Ex certified in their own right. The full conditions of use are given in the installation sheet. The P20-R is not certified for use in hazardous areas and must not be installed in any area classified as hazardous under AS/NZS 60079.10 (Zone 0, 1, 2, 20, 21 or 22).

Kemudahan Servis

Sepenuhnya dapat diservis di lapangan. Papan sirkuit listrik dapat dipertukarkan dan semua bagian P20 tersedia sebagai suku cadang; banyak bagian yang dapat dipertukarkan sehingga sakelar dapat dikonfigurasi sesuai kebutuhan. Kit cadangan dan seal tersedia dari Kelco Engineering atau distributor Anda.

Lainnya di Sakelar aliran inline