Seri QSakelar Pelampung Tugas Berat
Kerabat Seri K yang lebih besar dan lebih kokoh: pelampung polipropilena tugas berat yang di-overmould penuh di sekeliling kabel tiga inti berkualitas tinggi. Sakelar mikro S.P.D.T. tugas berat dengan rating 21 A pada 250 V AC, mampu mengendalikan motor pompa kecil secara langsung. Tertutup rapat, tahan manipulasi, tanpa bagian logam yang bersentuhan dengan cairan, dan sangat tahan bahan kimia.

Fitur
- Sakelar mikro Omron tugas berat 21 A (250 VAC resistif)
- Pelampung polipropilena ekstra kuat
- Sakelar tiga kawat S.P.D.T.
- Tanpa komponen merkuri atau timbal
- Kabel karet CPE berkualitas tinggi
- Tanpa bagian logam yang bersentuhan dengan cairan
- Desain tertutup dan tahan manipulasi
- Sangat tahan bahan kimia
- Tersedia berbagai ukuran kabel
Sakelar pelampung Seri Q terdiri dari pelampung polipropilena tugas berat yang di-overmould penuh di sekeliling kabel tiga inti berkualitas tinggi. Pelampung berisi sakelar single pole double throw (S.P.D.T.) yang men-trip ketika pelampung miring. Sakelar ini memberikan kontrol level cairan yang dapat diatur pada tangki, lubang, dan bendungan, dan penambatan kabel yang cermat menentukan aksi hidup atau mati pada posisi mana pun yang diinginkan. Sakelar tugas berat ini dapat mengendalikan motor pompa kecil secara langsung (beban minimum 160 mA pada 5 V DC). Pelampung terbuat dari polipropilena kelas tinggi, di-overmould penuh tanpa gland eksternal, dan terminasi sakelar dienkapsulasi dalam polipropilena untuk mencegah air merambat di sepanjang konduktor. Pelampung yang tertutup rapat, tanpa sambungan, dan tanpa gland ini benar-benar tahan manipulasi dan sangat kuat. Kabel tugas berat buatan khusus ini berisolasi EPR dan berselubung CPE, serta dirancang untuk terendam permanen dalam air. Sakelar dan kabelnya juga tahan terhadap oli, gemuk, lemak, air limbah, dan berbagai bahan kimia.
Informasi Lainnya
- Lembar Data Seri Q(versi bahasa Inggris)
- Instalasi Seri Q(versi bahasa Inggris)
- Informasi Pemberat Kabel(versi bahasa Inggris)
- Gambar Garis Seri Q 1 (DWG)
- Gambar Garis Seri Q 2 (DWG)
Pilih Model
Cara sakelar Seri Q bekerja
Aksi penyakelaran
Sakelar pelampung Seri Q yang mengendalikan tangki di antara level tinggi dan rendah.
Di sini pompa mengisi tangki, sehingga dihubungkan ke common (biru) dan normally closed (hitam); untuk mengosongkan tangki, gunakan common dan normally open (cokelat). Diferensial penyakelaran maksimum sekitar 300 mm di dalam air tanpa pemberat kabel (170 mm dengan pemberat kabel 100 mm dari pelampung). Pengkabelan dan diferensial berasal dari lembar data Seri Q.
Pemesanan: Model yang Tersedia
Batas Operasi
Data Listrik
Dimensi

Typical Applications
High and low level control; loss-of-prime protection for pumps; automatic control of sump pumps; control of tank filling and draining valves; level control in effluent and separation pits; level control in bulk-liquid tanks; control of level-warning equipment; alarms, pump control (direct or through a contactor or relay), and PLC / BMS inputs.
Suitable Liquids
The Q Series is suitable for use in clean water as well as in waste and effluents. It is a fully overmoulded polypropylene float with an EPR/CPE cable and has no metal parts in contact with the process liquid, so it can be used in water, seawater, acids, alkalis and a great variety of chemical solutions, including oil, oily waste, fats and effluent of many types. Not approved for use in potable water. No mercury is used in this switch.
QCW Cable Weight (separate accessory)
The QCW is a split heavy-grade polypropylene cable weight with a 316 stainless steel screw and nut. It clamps to the Q-series cable to act as the tether/pivot for the float’s tilt action when the float is suspended down a deep sump or pit. To fit it, unscrew the halves, place the cable in the channel, reassemble, position the weight on the cable where desired and tighten the halves, at least 100 mm from the float. With the cable weight mounted 100 mm from the float, the ON / OFF level change is reduced to 170 mm (300 mm maximum with no cable weight).
Installation
Avoid areas with excessive turbulence and anywhere the switch will rub or foul against any object — abrasion between the cable and adjacent surfaces greatly reduces the life of the switch. Where several float switches are installed, keep the cables from tangling or abrading against each other. Where possible, tether the switch cable to a suitable standpipe, and do not tether the cable closer than 100 mm from the end of the cable boot. Keep the exposed rubber cable out of direct sunlight: at the top of a tank, terminate the float switch in a suitable junction box rather than draping the cable over the tank rim or across exposed ground. Multiple float switches can be tidily installed using a length of PVC pipe as a central cable conduit, or a float switch can be strapped to a pump discharge pipe with cable ties.
Wiring
Connection is via three core 1.0 mm² S07RN-F (EPR/CPE) cable. The cable cannot be replaced; if it is damaged, replace the complete switch. The blue wire is common. With the switch hanging vertically down, black to blue is closed and brown to blue is open; if the switch is inverted (cable hanging vertically below the switch), blue to black is open circuit and blue to brown is closed. Most applications only need the common (blue) wire and either the black or brown wire — in all two-wire applications, insulate the end of the unused third wire, as it will become live when the switch changes state. Terminate the float switch in a junction box as close as practical and well above the liquid level, and avoid running the cable any appreciable distance through conduit.
Using Two Float Switches
The difference in height between the on and the off point is 300 mm (approximately), in water. For applications where the level change is greater than 300 mm, use two switches, one to actuate at high level and one at low level. Where two float switches are used in a control circuit, for example for filling or pumping out a deep tank, a relay must be used in the control circuit: a double pole relay latches the circuit ON, and the latch is broken by either the high level or the low level float switch changing state. A suitable relay may directly control the pump motor, but it is preferable that the control circuit is operated at low voltage with the relay contacts used to control a suitable mains voltage contactor, which in turn controls the pump motor.
Hazardous Areas
The Q Series is not certified for use in hazardous areas and must not be installed in any area classified as hazardous under AS/NZS 60079.10 (Zone 0, 1, 2, 20, 21 or 22).
Safety Note
The Q Series is a mains voltage device rated 250 V AC, but local electrical codes may require the switch to be isolated to a low voltage supply regardless of its high voltage rating. In the interest of safety, lower voltages, such as 24 or 48 volts, should be used wherever possible. Check with your local electrical authority before connecting to a mains voltage supply. If the switch is used in a 240 volt control circuit, it must always be isolated via a residual current device (RCD). All electrical work must be carried out by a qualified, licensed electrician and conform to AS/NZS 3000 (or equivalent) standards and local wiring rules. Ensure the float is installed where it will not be subjected to entanglement, severe agitation or abrasion against tank walls or moving equipment.
Kemudahan Servis
Unit tertutup, bagian dalamnya tidak dapat diservis oleh pengguna. Kabel tidak dapat diganti; jika rusak, ganti seluruh sakelar. Pemberat kabel QCW tersedia dari Kelco Engineering atau distributor Anda.