Seri TWMSakelar Aliran Tipe Kawat (Trailing Wire) Tugas Berat
Sakelar tipe kawat (trailing wire) kelas pertambangan/industri dalam bodi aluminium billet dengan sambungan proses baja tahan karat 316 1", untuk aplikasi pertambangan yang berat. Cocok untuk aplikasi pembuangan terbuka dan pipa 50 mm (2") ke atas. Tahan tekanan tinggi, slurry abrasif, limbah, serat, dan kecepatan aliran tinggi. Pengesampingan manual bawaan.

Fitur
- Sensor kawat (trailing wire), tanpa paddle yang dapat terkotori atau tersangkut
- Sakelar S.P.D.T. 5 hingga 500 V AC, 15 A (model 'H')
- Tersedia model 'L' kontak emas tegangan rendah
- Sambungan proses baja tahan karat 316
- Bodi aluminium billet tahan benturan tinggi
- Cocok untuk aplikasi pertambangan yang berat
- Pengesampingan manual bawaan
- Pilihan ulir 1" BSP atau NPT
- Tekanan nominal 400 bar / 5800 psi
- Suhu cairan minimum -60 °C / -76 °F
- Penggerak magnetik tanpa seal
- Sepenuhnya dapat diatur
- Bodi aluminium billet kedap air IP67
- Mudah diservis
Seri TWM menggunakan konsep sensor kawat (trailing wire) yang sama dengan Seri TW, tetapi dengan bodi yang lebih kokoh untuk aplikasi yang paling berat. Sensor kawat baja tahan karat yang fleksibel menawarkan keunggulan besar dibandingkan paddle konvensional bila terdapat padatan atau semi-padatan, seperti pada pemompaan limbah, dan juga cocok untuk aplikasi slurry dan pertambangan serta banyak situasi pemompaan normal di mana kecepatan aliran tinggi dan paddle tidak sesuai. Sambungan proses baja tahan karat 316 1" satu bagian (BSP atau NPT) dan bodi sakelar yang dimesin dari aluminium billet padat. Sakelar mikro S.P.D.T. 500 V untuk sirkuit kendali umum dipasok sebagai standar (model 'H', 5 hingga 500 V AC, 15 A, cocok untuk starter pompa, logika relai, kontaktor, dan timer); sakelar kontak emas tegangan rendah (model 'L') tersedia untuk sirkuit PLC dan instrumentasi. Kedua model memiliki pengesampingan manual bawaan.
Informasi Lainnya
Lembar data lokal belum tersedia untuk produk ini dalam bahasa yang Anda pilih. Tautan di bawah membuka versi bahasa Inggris.
Pemesanan: Model yang Tersedia
Batas Operasi
Data Listrik
Dimensi

Warning: Electrical Safety
The TWM Series is a mains voltage device - incorrect installation can cause death or serious injury. All electrical work must be carried out by a licensed electrician.
Manual Override
All TWM-H and TWM-L models include a built-in manual override button. Pressing it switches the flow switch on regardless of flow — useful for manually starting pumps in spite of an initial lack of flow, and for testing/commissioning. To test after wiring, press the red manual override button under the cable gland; the switch changes state as if liquid were pushing the trailing wire.
Wire Length / Sensitivity
The flow rate required to actuate the TWM depends on many variables such as turbulence, liquid viscosity and the surface area of sensor wire exposed to the flow. The wire is made in fixed lengths of 50, 80, 100, 140, 160, 180, 200, 250 or 300 mm, measured from the tip of the wire to the bottom end face of the process connection, and the required length must be specified when ordering (e.g. TWM-H-25B-100). Use the online Paddle Trimming Calculator to find the optimum wire length: enter your pipe inside diameter, flow rate and liquid to check the switch will operate reliably at your flow.
Installation & Mounting
Mount in a pipe tee, tapping saddle or weld-on socket. For effluent or liquids carrying solids, use a stand-off tee (50 mm (2") or larger) so the switch body sits out of the line of flow; the arrow on the switch must point in the direction of flow. The switch suits full or partially full pipe and can go in suction or delivery pipework, horizontal or vertical. In vertical pipe, flow must be upward. Do not mount on the underside of horizontal pipe. Where possible, mount the switch away from pumps, valves and bends: a fitting directly upstream makes the flow uneven and turbulent at the wire sensor, which can shift the switching point slightly or make the wire flutter near the switching point, while downstream fittings have little effect. If the switch has to go close to a fitting, enter the upstream straight length in the Paddle Trimming Calculator and check operation on commissioning. Seal the thread with PTFE tape or thread sealant, leaving at least 4 mm of thread above the socket, and tighten with a spanner on the spanner flats only — never twist the switch body.
Adjusting Sensitivity
Switches are supplied at maximum sensitivity (adjuster wound fully in). To decrease sensitivity, remove the red dust cap and wind the adjusting screw out (anti-clockwise) with a wide flat screwdriver. The further out the screw, the more flow is needed to operate the switch. Refit the dust cap.
Earthing
The TWM has an aluminium housing. For all mains voltage applications it must be earthed using the dedicated earth terminal inside the housing.
Sewage / Slurry / Mining
The flexible stainless wire sensor offers major advantages over conventional paddles where solids or semi-solids are present, such as in sewage pumping, and is also suitable for slurry and mining applications and for many normal pumping situations where the flow velocity is high and paddles are unsuitable. Designed for the toughest paddle-unsuitable services: sewage pumps where rags and fibres would foul a paddle, slurries with abrasive solids, and mining applications with high-velocity dirty water. The flexible wire flexes with the flow, accumulates less debris, and survives velocities that fatigue a paddle.
Hazardous Areas
The TWM-H is not certified for use in hazardous areas and must not be installed in any area classified as hazardous under AS/NZS 60079.10 (Zone 0, 1, 2, 20, 21 or 22). The TWM-L is simple apparatus under AS/NZS 60079.11 and may be used in a hazardous area only as part of an intrinsically safe circuit, connected through suitably certified associated apparatus. It is not Ex certified in its own right. The associated apparatus must not exceed Uo ≤ 30 V, Io ≤ 100 mA. The full conditions of use are given in the installation sheet.
Replacing the Trailing Wire & Arm
The trailing wire sensor and its arm and pivot bearing are replaceable items. Spare parts, including replacement trailing wire sensors and arm assemblies, are available from your supplier; quote the part number of the trailing wire switch when ordering. To replace the wire, unscrew it from the main switch arm using the spanner flats on its top screw (right-hand thread), fit the replacement and fully tighten the screw (a drop of Loctite Stud Lock can be added for extra security; the small O-ring on the screw normally acts as a lock washer). Replacement arms are supplied complete with a new bronze bearing and are held by a pivot bolt in the side of the process adaptor. Never undo or remove the sealed hexagonal cap at the top of the main arm — it contains a magnet oriented for proper operation of the switch.
Approved Standards
The 'H' and 'L' microswitches used in the TWM Series are approved to UL1054 (File E41515), CSA C22.2 No.55 (File LR21642) and EN61058-1, and are CE marked.
Kemudahan Servis
Mudah diservis dan sepenuhnya dapat diservis di lapangan. Sakelar aliran tipe kawat (trailing wire) TWM sangat mudah diservis, dan sebagian besar komponen tersedia sebagai kit suku cadang; suku cadang, termasuk sensor kawat (trailing wire) pengganti dan rakitan lengan, tersedia dari pemasok Anda. Satu sekrup yang dapat dijangkau dari luar melepas enklosur listrik dari bagian basah (wet-end). Kawat, seal, dan sakelar pengganti tersedia dari Kelco Engineering atau distributor Anda.